Control unauthorized egress while maintaining life-safety requirements with the Detex V40EE-PSO-628-48 Delayed Egress Rim Exit Device.
Built on the Detex Value Series V40 Grade 1 platform, this electrified rim exit device provides a standard 15-second delayed-egress function and an approximately 100 dB alarm when an unauthorized exit attempt is made.
This configuration is designed for 48" / 4-foot doors, features a 628 Satin Aluminum finish, and is supplied without the power supply for installations where a compatible Detex 24VDC filtered and regulated power supply is already provided.
Key Features
-
Genuine Detex Value Series V40
-
Delayed Egress EE function
-
Standard 15-second release delay
-
Approximately 100 dB alarm
-
PSO / PS0 – Less Power Supply
-
Designed for 48" / 4-foot doors
-
628 Satin Aluminum finish
-
Rim exit-device configuration
-
Standard 99 Surface Strike
-
Cylinder dogging standard unless otherwise specified
-
15-second arming delay
-
1-second nuisance delay
-
Deadlatch monitoring
-
Remote alarm relay output
-
Remote reset capability
-
Bypass alarm input
-
Low-battery alert
-
Red and green LED indication
-
Fire-alarm interface through compatible power supply
-
3/4" stainless-steel deadlocking Pullman latchbolt
-
Non-handed
-
Field sizeable
-
Heavy-duty commercial construction
EE – Delayed Egress
The Detex EE Delayed Egress function is designed to discourage unauthorized use of an emergency exit while still allowing egress after the code-required delay.
When an armed device detects an exit attempt:
-
The alarm activates at approximately 100 dB.
-
The delayed-egress timer begins.
-
The door remains secured during the standard 15-second delay.
-
After the delay expires, the door can be opened.
Detex states that its EE system is intended for primary and secondary exits where controlling unauthorized egress is required.
15-Second Delayed Release
The standard configuration provides:
Delayed Egress: 15 Seconds
Detex also offers a factory-configured 30-second option where permitted by applicable codes and the Authority Having Jurisdiction.
The standard product should not be assumed to provide a 30-second delay unless that option is specifically ordered.
Approximately 100 dB Alarm
The integrated alarm sounds during an unauthorized exit attempt to alert facility personnel and discourage continued egress.
The standard EE configuration includes:
-
Approximately 100 dB alarm
-
Green LED
-
Red LED
-
Audible/visual status indication
-
Delayed-egress signage
PSO / PS0 – Less Power Supply
This particular SKU is supplied without the external power supply.
Detex Option Code
PS0 – Less Power Supply
Some distributor systems display this as:
PSO
The function is the same: no power supply is included with this device.
A compatible 24VDC filtered and regulated power supply is required for operation.
This configuration is especially useful for:
-
The second delayed-egress device on a pair of doors
-
Replacement-device installations
-
Projects where an existing compatible Detex power supply is already installed
-
Centralized power-supply applications
Detex states that one compatible EE power supply can power both delayed-egress devices on a pair of doors, with the second device ordered using the PS0 option.
Fire Alarm Interface
Delayed-egress installations require appropriate life-safety system integration.
Detex provides for a fire-alarm input at the power supply, allowing the delayed-egress locking function to be overridden during an emergency as required by applicable codes.
Because this particular PSO/PS0 device does not include the power supply, verify that the power supply selected for the opening provides the required fire-alarm interface.
9V Battery Backup
The EE system uses a 9V backup battery for the alarm function during a power failure.
The battery does not operate the delayed-locking function during loss of primary 24VDC power.
Cylinder Dogging & Arming
Cylinder dogging is standard with the Value Series EE package unless LD – Less Dogging is specifically ordered.
A compatible mortise cylinder is used for authorized system control.
Mortise cylinder is not included unless specifically ordered.
Detex also provides the LD configuration when mechanical dogging is not required.
48" / 4-Foot Door Configuration
This listing is specifically for:
Device Length: 48"
Door Width: 4'0"
The standard V40 is supplied as a 36" device, while 48" is the designated option for 4-foot doors.
99 Surface Strike
The standard wide-stile V40 rim exit device uses the:
Detex 99 Surface Strike
The 99 strike is intended for compatible single-door rim exit-device installations.
628 Satin Aluminum
BHMA Finish: 628
US Finish: US28
Description: Satin / Clear Anodized Aluminum
The 628 finish is the standard V40 aluminum-baseplate finish and coordinates well with commercial aluminum storefront and architectural hardware.
Heavy-Duty V40 Construction
The Detex V40 platform features:
-
3/4" stainless-steel deadlocking Pullman latchbolt
-
Heavy-duty ribbed aluminum rail
-
Steel-reinforced pushpad construction
-
Non-handed design
-
Field-sizeable construction
-
Modular outside-trim compatibility
-
Angled end cap designed to deflect impact
The V40 is designed as Grade 1 panic and fire-exit hardware.
Typical Applications
Ideal for:
-
Retail emergency exits
-
Loss-prevention openings
-
Schools and universities
-
Hospitals
-
Healthcare facilities
-
Government buildings
-
Airports
-
Warehouses
-
Distribution centers
-
Commercial facilities
-
Restricted egress openings
-
High-value inventory areas
Product Specifications
Brand: Detex
Series: Value Series V40
Model: V40EE-PSO-628-48
Manufacturer Option: PS0 – Less Power Supply
Product Type: Delayed Egress Rim Exit Device
Function: EE – Delayed Egress
Standard Delay: 15 Seconds
Alarm: Approximately 100 dB
Device Length: 48"
Door Width: 4'0"
Strike: 99 Surface Strike
Finish: 628 / US28
Finish Description: Satin Aluminum
Latchbolt: 3/4" Stainless-Steel Deadlocking Pullman Type
Dogging: Cylinder Dogging Standard Unless Otherwise Specified
Handing: Non-Handed
Sizing: Field Sizeable
Required Power: 24VDC Filtered & Regulated
Power Supply Included: No
Fire Alarm Interface: Required Through Compatible Power Supply
Battery Backup: 9V – Alarm Function Only
What's Included
-
Detex V40 48" rim exit device
-
EE delayed-egress electronics
-
Approximately 100 dB alarm
-
Red and green LED indicators
-
99 surface strike
-
628 Satin Aluminum finish
-
Standard delayed-egress signage/components supplied with the selected configuration
Not Included
-
24VDC power supply
-
Mortise cylinder unless specifically ordered
-
Exterior trim
-
Access-control reader
-
Electric hinge or power transfer
-
Door or frame
-
Additional system accessories
Important Ordering Information
Before ordering, verify:
-
48" / 4-foot door
-
Rim exit-device application
-
628 finish
-
15-second delayed-egress requirement
-
99 surface-strike compatibility
-
Existing compatible 24VDC power supply
-
Fire-alarm interface requirements
-
Required mortise cylinder
-
Outside trim requirements
-
Local delayed-egress code requirements
Delayed-egress hardware must be installed in accordance with applicable building, fire, and life-safety codes and requirements of the Authority Having Jurisdiction.
Recently viewed products
Describe your recently viewed products here