Detex ECL-1576-15 Cam Bridge Assembly | ECL-230D Replacement Part
Detex ECL-1576-15 Cam Bridge Assembly | ECL-230D Replacement Part
Detex ECL-1576-15 Cam Bridge Assembly | ECL-230D Replacement Part
$31.04
/
Pickup available at Shop location
Usually ready in 24 hours
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
OEM Replacement Cam Bridge | ECL-230D Exit Control Lock Mechanism
Restore proper mechanical operation and cylinder timing in a compatible Detex ECL-230D Exit Control Lock with the genuine Detex ECL-1576-15 Cam Bridge Assembly.
The ECL-1576-15 is a factory replacement component located inside the ECL-230D's main locking mechanism. Detex identifies it as Item 1a – Cam Bridge Assembly within the complete ECL-243PH Mechanism Assembly.
Key Features
-
Genuine Detex replacement part
-
Part Number ECL-1576-15
-
Factory Cam Bridge Assembly
-
Designed for compatible Detex ECL-230D exit control locks
-
Internal component of the ECL-243PH Mechanism Assembly
-
Used in the key/cylinder operating mechanism
-
Provides adjustment point for rim-cylinder timing
-
Ideal for repair and refurbishment
-
Component-level replacement part
-
Helps restore proper locking, unlocking, and alarm sequencing
-
Cam Bridge Assembly only
-
Complete mechanism assembly not included
Factory ECL-230D Replacement Part
Detex's current ECL-230D factory parts breakdown lists:
Item 1a
Part Number: ECL-1576-15
Description: Cam Bridge Assembly
The cam bridge is one of the individual components that make up the larger ECL-243PH Mechanism Assembly.
Controls Rim-Cylinder Timing
The cam bridge plays an important role in coordinating operation of the key cylinder with the ECL-230D locking and alarm mechanism.
Detex specifically advises that when an ECL-230D remains in alarm after the key has been removed, rim-cylinder timing may require adjustment at the cam bridge assembly.
Proper timing helps coordinate:
-
Key rotation
-
Deadbolt operation
-
Alarm arming
-
Alarm disarming
-
Internal mechanism sequencing
ECL-230D Application
The ECL-1576-15 is shown in Detex factory documentation as an internal part of the ECL-230D Exit Control Lock mechanism.
The ECL-230D itself is a battery-alarmed commercial exit-control lock featuring a 1" throw deadbolt, rim-cylinder operation, and an audible alarm for protected secondary exits.
Part of the ECL-243PH Mechanism Assembly
The complete Detex ECL-243PH Mechanism Assembly includes multiple serviceable components:
-
ECL-1576-15 – Cam Bridge Assembly
-
ECL-285A – Cam Plate Bottom
-
ECL-306-1 – Bolt Assembly
-
ECL-284 – Detent Spring
-
ECL-293A – Detent Lever & Roller Assembly
-
ECL-1576-20 – Actuator & Release Lever Kit
-
Compatible siren-switch assembly components
This listing is specifically for the ECL-1576-15 Cam Bridge Assembly, not the complete ECL-243PH mechanism.
Common Service Symptoms
The cam bridge should be inspected when troubleshooting issues such as:
-
Alarm remaining active after the key is removed
-
Improper rim-cylinder timing
-
Locking or unlocking sequence problems
-
Incorrect alarm arming/disarming sequence
-
Mechanical wear in the existing cam bridge
-
Damage discovered during an ECL-230D overhaul
Detex notes that improper cylinder timing can cause the device to remain in alarm and directs technicians to the cam bridge assembly for timing adjustment.
Important Diagnostic Note
Replacing the cam bridge should be based on proper diagnosis.
Before replacing the ECL-1576-15, inspect:
-
Rim cylinder
-
Cylinder timing
-
Cam plate
-
Bolt assembly
-
Detent spring
-
Detent lever and roller
-
Actuator and release lever
-
Alarm switch
-
Battery
-
Strike alignment
A timing problem may sometimes require adjustment rather than replacement of the cam bridge itself.
Product Specifications
Manufacturer: Detex
Part Number: ECL-1576-15
Product Type: Cam Bridge Assembly
Primary Application: Detex ECL-230D
Factory Diagram Item: 1a
Parent Assembly: ECL-243PH Mechanism Assembly
Function: Mechanical Cam / Cylinder Timing Component
Installation Location: Internal Exit-Control Lock Mechanism
Use: Replacement / Repair / Refurbishment
Product Type: OEM Service Part
ECL-230D Mechanism Reference
The ECL-230D mechanism contains several components that work together to operate the deadbolt and alarm system.
The cam bridge interfaces with the locking mechanism so that cylinder rotation occurs in the correct relationship to the mechanical and alarm functions.
Correct installation and adjustment are important for dependable operation.
Common Applications
Used for servicing Detex ECL-230D devices installed at:
-
Emergency exits
-
Retail stores
-
Warehouses
-
Schools
-
Universities
-
Hospitals
-
Healthcare facilities
-
Government buildings
-
Manufacturing facilities
-
Office buildings
-
Commercial facilities
-
Institutional buildings
-
Restricted secondary exits
Replacement vs. Complete Mechanism
ECL-1576-15
Use when the cam bridge itself requires replacement.
ECL-243PH
The ECL-243PH is the complete mechanism assembly containing the cam bridge and additional internal mechanism components.
If several internal components are damaged or heavily worn, replacing the complete mechanism assembly may be more appropriate.
Important Compatibility Note
Before ordering, verify:
-
Existing device is a compatible Detex ECL-230D
-
Existing replacement part number is ECL-1576-15
-
Cam bridge has been correctly diagnosed
-
Rim-cylinder timing has been checked
-
Remaining mechanism components are serviceable
Do not select this component solely by appearance.
What's Included
(1) Detex ECL-1576-15 Cam Bridge Assembly